Application and tool settings
Open Settings in the main window. The following sections apply to beta testers. Control names match the application interface.
| Section | Purpose |
|---|---|
| Account | Sign-in, activation, license expiry and autonomous use |
Application → Profile | Select a profile and module |
| Application → Profile → Diagnostic database | Server VAG data, ODIS indexing, or independent installation |
Application → Startup | Automatic connection and active serial port scanning |
Application → Personalization | Theme and accent color |
| Connections → Transport | Communication source and connection parameters |
| Connections → Driver Bridge | 32-bit J2534 driver bridge, when the component is installed |
Tracer | Import folder and quick-label shortcut |
Monitor | Data change highlighting |
| Packages | Install, repair and update components |
| MCP Server | Agent permissions and McpBridge control |
Logging | Technical log file and recent events |
Without a valid license, some settings are hidden; account, appearance and logging remain available. A group containing only one page may display that page without an intermediate group node.
Startup
Automatic connection on start-up allows connecting at startup with saved parameters. Check the selected module, port and speed before enabling it.
Active adapter detection
Active serial port scanning in Settings → Application → Startup allows automatic identification of CAN adapters through serial ports, including ELM327, at startup and during background list updates.
Possible unwanted traffic
Active detection opens ports and sends data to connected devices. Depending on the device, this data may reach the bus and generate unwanted traffic. This can happen as soon as the application starts, before you connect to the line in the application, and when you click Rescan.
If additional traffic is unacceptable, disable Active serial port scanning before starting the application with an adapter attached to the working bus. If necessary, disconnect the adapter from the bus first, start the application, and change the setting. When disabled, background discovery lists ports without exchanging probe commands. The setting applies to the next scan; disabling it does not turn off automatic connection.
An explicit Rescan checks devices of the selected type even when automatic scanning is disabled. Opening transport settings and selecting an adapter also reads information from the selected device. These actions may open the port and send commands.
Diagnostic database
In Automotive → VAG, the Diagnostic database block appears below the profile selection. Database source offers server and local data. For local data, index an existing ODIS installation or prepare an independent installation from ODIS/Postsetup.
See VAG diagnostic database for a comparison of methods, access requirements, setup steps, updates, and data removal.
Appearance
Theme selects Auto, Dark or Light. Auto follows the Windows theme. Use system accent color follows the system accent; disable it to select a custom color.
Tracer
Remember last import folderremembers the folder used for loading traces.Capture → Quick label shortcutselects a quick-label key with the requiredCtrlmodifier. The default isCtrl+L.
The details panel position, size and pin state, CAN column widths and filter expressions are saved while using Tracer. These are display preferences, not adapter settings.
Monitor
Dynamic highlight controls how data changes are displayed:
| Setting | Effect |
|---|---|
Enabled | Enables dynamic highlighting |
Stale after, s | Time since the last value change until its highlight fully fades, from 3 to 60 seconds |
Stale data opacity | Opacity of an unchanged value, from 0 to 1 |
Lost after, s | Time since the last data observation until the row fully fades, from 3 to 60 seconds |
Lost data opacity | Opacity of an row with lost data, from 0 to 1 |
Stale means a value has not changed recently: repeated identical data remains current. Lost means no new data has been observed within the selected interval. It indicates age, not a data error. Observing data again restores the row's opacity, but an identical value does not restart the change highlight.
Highlighting is enabled by default: stale after 3 seconds, lost after 10 seconds, and stale data opacity 0.6. The intervals are independent and fading is gradual. Settings apply immediately to CAN and Modbus, are saved, and do not change the communication rate or device polling period. When loading older settings, the previous shared interval is used for both effects with a minimum of 3 seconds; a previous zero value keeps highlighting disabled.
For logs and issue reports, see diagnostics and support.